MSL-101 Lock


    Safes with this Lock:
  1. MFL Depository [early models]
    These safes no longer come standard with this lock.

    IMPORTANT:
  1. To ensure the safety of your belongings, you MUST change the factory set code to your own unique code immediately!

FEATURES:

MSL-101
      Two Code Capacity
    1. User Code: Factory Set
    2. Master Code: Factory Set
      Please see your user manual for the factory set Codes
      or contact Tech Support.

      1. NOTE:
      2. If the safe is opened with the override code it will set the User Code back to the factory default.
        WE HIGHLY RECOMMEND THAT YOU CHANGE THE FACTORY SET OVERRIDE CODE.

      Wrong Code Penalty
    1. Entry of 3 consecutive invalid codes results in a 1 minute delay period.
      Audio/Visual Signals
    1. Double Signal : 2 flashes & 2 beeps - indicates entry is valid or accepted.
    2. Triple Signal : 3 flashes & 3 beeps - indicates invalid or not accepted.
      Automatic Re-Locker
    1. The controller will re-lock in 4 seconds after a valid entry is made and the door is open.
      Low Battery Alert
    1. Controller repeated beeping during an unlocking indicates that the battery is low & needs immediate replacement.
    2. Manufacturer recommends the use of 9V Alkaline Batteries & an annual maintenance replacement of the batteries.
      Single & Dual User Mode
    1. Single Mode : Open lock with 1 code [Override or User Code]
    2. Dual Mode : Open lock with 2 codes [User 1 & User 2 Code]
      Time Delay
    1. Time Delay : A time period waiting for opening lock. The maximum Time Delay is 99 minutes

OPERATING INSTRUCTIONS:

      Always Perform this operation with the door open
    1. Before closing the door, make sure all the changes are correct.
      Change Master Code [3-8 digits]
    1. Enter : #- Existing Master Code -#
      The light will stay Orange for 20 seconds
    2. Enter : New Code -#
      NOTE: The Master Code & User Code can be set to a 1-12 digits
    3. [[SET]] will display & LED is now Orange for 20 seconds
    4. Re-Enter : New Code -#
    5. [[OPEN]] will display & LED will signal twice confirming the code change is successful
    6. If a mistake is made wait 25 seconds and repeat steps 1 - 6
    NOTE:
  1. Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
  2. Operations between adjacent steps need be completed in 10 seconds. Otherwise, the lock system sets back to standby status.

    Open Lock [Single User Mode]
  1. Enter : *- User Code -#
  2. [[OPEN]] will display & LED will signal twice indicating a valid code.
  3. Turn the handle clockwise while [[OPEN]] is displayed & LED is Green
    Open Lock [Dual User Mode]
  1. Enter : *- User Code -#- Master Code -#
  2. [[OPEN]] will display & LED will signal twice indicating valid codes
  3. Turn the handle clockwise while [[OPEN]] is displayed & LED is Green
    NOTE: Valid Code - Lock will double signal
    Invalid Code - Lock will triple signal
    Set Time Delay
  1. Enter : #- Master Code -#
  2. [[SET]] will display & LED is now Orange for 20 seconds
  3. Enter : *- [01-99] -#- [01-99] -#
  4. [[OPEN]] will display & LED will signal twice confirming that the setting change is sucessful.
  5. Press : * or # to initiate the Time Delay
  6. [[SET]] will display & LED will signal once every 2 seconds indicating that the lock is in the delay period
  7. After the time delay period, a 2 minute window is given to enter code
  8. [[SET]] will display & LED will signal twice every 4 seconds during the 2 minute window

    NOTE:
  1. Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
  2. Operations between adjacent steps need be completed in 10 seconds. Otherwise, the lock system sets back to standby status.

    De-activate Time Delay
  1. Enter : #- Master Code -#
  2. [[SET]] will display & LED is now Orange for 20 seconds
  3. Enter : *-00-#-00-#
  4. [[OPEN]] will display & LED will signal twice confirming that the code setting is successful
    Set Single User Mode [Manager OR User Code to Unlock]
  1. Enter : #- Master Code -#
  2. [[SET]] will display & LED is now Orange for 20 seconds
  3. Enter : *-1-#-1-#
  4. [[OPEN]] will display & LED will signal twice confirming the setting change is successful
    Set Dual User Mode [Manager & User Code to Unlock]
  1. Enter : #- Master Code -#
  2. [[SET]] will display & LED is now Orange for 20 seconds
  3. Enter : *-2-#-2-#
  4. [[OPEN]] will display & LED will signal twice confirming the setting change is successful
    Low Battery Warning
  1. The LED light turns Red during an opening indicates that the battery is low and needs immediate replacement.
  2. Uses one 9V Alkaline Battery
    If batteries are depleted and will not allow lock to open, simply follow the instructions below.
    Lock contains a non-volatile memory, even with batteries removed the lock will retain all programming.
    Changing the Batteries
  1. Locate the battery cover on the bottom edge of the keypad and remove the cover by pulling on the tab.
  2. Carefully remove the used 9V Battery from the compartment.
    CAUTION! Hold onto battery connector to avoid pulling wires out of housing.
  3. Reinsert the new battery, do not force the battery into the compartment.
Please contact Tech Support at 888.381.8514 for assistance.