MSL-500 Lock


FEATURES:

MSL-50
      Seven Code Capacity
    1. Master Code: 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8
    2. Users can be programmed
      Wrong Code Penalty
    1. If three incorrect entries are entered in a row, the keypad will shut down for a period of five minutes.
      During this shut down period you will not get a response from the keypad.
      Audio/Visual Signals
    1. The Lock Has No Response (No Flash, No Beeps)
      Important: Make sure the wires in the keypad housing are not pinched and are securely connected.
      Low Battery Alert
    1. Controller repeated beeping during an unlocking indicates that the battery is low and needs immediate replacement.
    2. Manufacturer recommends the use of 9-Volt premier alkaline batteries and an annual maintenance replacement of the batteries.
      Single & Dual User Mode
    1. Single Mode: Open lock with one (1) code (override or user code).
    2. Dual Mode: Open lock with two (2) codes (user1 and user2 code).
      Time Delay
    1. Time Delay: A time period waiting for opening lock. The maximum Time Delay is ninty nine (99) minutes.

OPERATING INSTRUCTIONS:

      Always Perfrom this operation with the door open
    1. Before closing the door, make sure all the changes are correct.
      Quick Start
      Change Master Code [3 - 8 digit code]
    1. Input: * - * (lock will beep twice)
    2. Input: 8 - 8 - 8 - # (lock will beep twice)
    3. Input: Current Master Code - # (lock will beep twice)
    4. Input: New Master Code - # (lock will beep twice)
    5. Re-Input: New Master Code - # (light stays green for three (3) seconds)
      Example: * - * - 8 - 8 - 8 - # - Master Code - # - New Master Code - # - New Master Code - #.
      Unsuccessful Code Change: five beeps (the old code is still valid), repeat steps 1 - 5.

      NOTE:
    1. Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
    2. Operations between adjacent steps need be completed in 10 seconds. Otherwise, the lock system sets back to standby status.

      Activate User Code [3 - 8 digit code]
    1. Input: * - * (lock will beep twice)
    2. Input: 3 - 3 - 3 - # (lock will beep twice)
    3. Input: Current Master Code - # (lock will beep twice)
    4. Input (User #) - # (User #: Specify which user you would like to activate: 1, 2, 3, 4, or 5)
    5. Input: New User Code - # (lock will beep twice)
    6. Re-Input: New User Code - # (light stays green for three (3) seoncds)
      Example: * - * - 3 - 3 - 3 - # - Master Code - # - 4 - # - New User Code - # - New User Code - #.
      [This will activate User 4]
      Unsuccessful Code Activation: five beeps, repeat steps 1 - 6.
      Changing the User Code [3 - 8 digit code]
    1. Input: * - * (lock will beep twice)
    2. Input: 4 - 4 - 4 - # (lock will beep twice)
    3. Input: Current User Code - # (lock will beep twice)
    4. Input: (User #) - # (User #: Enter the user # that identifies the Current User Code on step 3)
    5. Input: New User Code - # (lock will beep twice)
    6. Re-Input: New User Code - # (light stays green for three (3) seconds)
      Example: * - * - 3 - 3 - 3 - # - User 2 Code - # - 2 - # - New User Code - # - New User - #.
      [This will change User 2's Code]
      Unsuccessful Code Activation: five beeps, repeat steps 1 - 6.
      Deleting the User Code
    1. Input: * - * (the lock will beep twice)
    2. Input: 6 - 6 - 6 - # (the lock will beep twice)
    3. Input: Current Master Code - # (the lock will beep twice)
    4. Input: (User #) - # (the lock will beep twice)
      [User #: Specify which user you would like to delete: 1, 2, 3, 4 or 5]
    5. Re-Input: (User #) - # (light stays green for three (3) seconds) Example: * - * - 6 - 6 - 6 - # - Master Code - # - 5 - # - 5 - #.
      [This will delete User 5]
      Unsuccessful Code Change: five beeps, repeat steps 1 - 5.
      Open Lock [Single User Mode]
    1. Enter: * - Code - #
    2. The lock will indicate a valid code entry with a single signal and the open light will stay green for five (5) seconds.
    3. Turn the handle clockwise before the green light disappears.
      Set Time Delay [1 to 59 minute time delay]
    1. Input: * - * (the lock will beep twice)
    2. Input: 1 - 5 - 9 - # (the lock will beep twice)
    3. Input: Current Master Code - # (the lock will beep twice)
    4. Input: (00 - 59) - # (light stays green for three (3) seconds)
      01 = 1 minute time delay
      59 = 59 minute time delay
      00 = Will turn time delay mode off
      Example: * - * - 1 - 5 - 9 - # - Master Code - # - 03 - #. [This will set the time delay period to 3 minutes]
    5. Unsuccessful Code Change: five beeps, repeat steps 1 - 4.

      NOTE:
    1. The Master Code will override the time delay.

      Opening Lock with Time Delay Set to 1
    1. Enter any valid code other than the Master Code.
    2. Once the code is entered the time delay will activate.
    3. During the time delay, codes will not be accepted, when you press any key the light will stay orange for three (3) seconds.
    4. The lock will beep continuously and the light will stay green for the last thirty (30) seconds of the time delay period.
    5. Once the continuous beeps stop, the lock will unlock for five (5) seconds.
    6. Turn the handle to open safe.
      Set Single User Mode [Default]
    1. Input: Code - # (light stays green for five (5) seconds)
    2. Turn the handle clockwise before the green light disappears.
      Example: 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - #.
      Invalid Code: a solid red light along with five beeps.
      Set Dual User Mode
    1. Input: 1st Code - # (lock will beep twice)
    2. Input: 2nd Code - # (light stays green for five (5) seconds)
    3. Turn the handle clockwise before the green light disappears.
      Example: 1st Code - # - 2nd Code - #.
      Invalid Code: a solid red light along with five beeps.
      Wrong try penalty: If four incorrect entries are entered in a row, the keypad will shut down for a period of five (5) minutes. During this shut down period the keypad will not accept any codes
      Low Battery Warning
    1. Red light appears when you open the safe other than the green light.
    2. Enter your code and get a valid response but the lock doesn't unlock.
      Changing the Batteries
    1. Locate the battery cover on the bottom edge of the keypad and remove the cover by pulling on the tab.
    2. Carefully and gently remove the 9-volt battery from the compartment. CAUTION! Hold onto battery connector to avoid pulling wires out of housing.
    3. Carefully reinsert the new 9V alkaline battery, do not force the battery into the compartment.
    4. The lock will retain all current codes and settings.

TROUBLESHOOTING THE LOCK:

      The Lock Has No Response [No Beeps]
    1. Make Sure the battery wires in the keypad housing are not pinched and are securely connected.
      Lock can possibly be in the lockout penalty, wait five (5) minutes and check if the lock responds [See Wrong Try Penalty]
    2. Replace the existing batteries with new ones. [See Changing the Batteries]
      The Lock Is Responding But Does Not Unlock
    1. Make sure you are getting a valid response.
    2. Make sure you get a signal with every key stroke.
    3. Make sure you are not in time delay mode. [See How to Open In Time Delay]
    4. Replace the existing batteries with new ones. [See Changing the Batteries]
    5. If the lock still does not open, contact Mesa Safe Company Tech Support: 888.381.8514 [Available Mon - Fri, 8:00am - 5:00pm PST]
      IMPORTANT: DO NOT RETURN SAFE TO STORE If you are missing parts, have difficulty programming or opening your safe or have any other questions regarding the use and care of your safe
      Please contact Tech Support at 888.381.8514 for assistance.
      Basic Features & Functions
    1. 6 Personal Codes available. Keep notes on which code belongs to which user (Users: Master, User 1, User 2, User 3, User 4 and User 5).
    2. The Mesa Model MSL-500 Electronic Lock is shipped from the factory with a factory set master code. You should set the lock to your own unique master code immediately.
    3. If four incorrect entries are entered in a row, the keypad will shut down for a period of five (5) minutes.
      During this shut down period the keypad will not accept any codes.
    4. Programmable time delay function can be set from 01 minute to 59 minutes.
      Optional dual user mode, in this mode two separate codes will need to be entered to unlock safe.
Please contact Tech Support at 888.381.8514 for assistance.
Live Technical Support Available Monday - Friday 8:00am - 4:30pm [Pacific Standard Time]
Click Here to view our Mesa Safe Warranty.
Click Here to view our Limited Lifetime MBF Gun Safe Warranty.