    IMPORTANT:
  1. To ensure the safety of your belongings, you MUST change the factory set code to your own unique code immediately!

FEATURES:

ESCL-0601-A-D
      Four Code Capacity
    1. Super Code: Reset lock back to manufacturer default status
    2. Master Code: Open lock, set lock functions, & manage manager. Manufacturer Default Code is factory set
      Please see your user manual for the factory set Codes or contact Tech Support.
    3. Manager Code: Open lock & manage user. No default setting & end-user need to set code before operating lock
    4. User Code: Open lock. No default setting & end-user need to set code before operating lock
      Wrong Entry Penalty
      Entry of 4 consecutive invalid codes results in a 5 minute delay period
    1. The lock beeps at 5 second intervals
    2. During delay period, removing batteries, the controller stops counting time; reinstalling batteries, the keypad continues to count down until 5 minutes delay period finishes.
      Standby Status
      The controller will turn into a standby status with a long beep sound if there is no operation in 10 seconds after the system is activated.
    1. Automatic Re-lock
      The controller will re-lock in 4 seconds after a valid entry is made and the door is open
    2. Low Battery Alert
    3. Controller repeated beeping during an unlocking indicates that the battery is low & needs immediate replacement
    4. Manufacturer recommends the use of 9V Alkaline Batteries & an annual maintenance replacement of the batteries
      Single & Dual User Mode
    1. Single Mode: Open lock with 1 Code [Manager or User Code]
    2. Dual Mode: Open lock with 2 Codes [Manager & User Code]
      Time Delay & Time Window
    1. Time Delay: A time period waiting for opening lock. The maximum Time Delay is 40 minutes
    2. Time Window: A time period for entering code(s) to open lock after Time Delay. The maximum Time Window is 20 minutes

OPERATING INSTRUCTIONS:

      Always perform this operation with the door open
    1. Before closing the door, make sure all the changes are correct.
      QUICK START
      Change Master Code
    1. Enter : 0-0-0-0-0-0
      One Beep sounds, which indicates the entry is valid & the system is waiting for code changing
    2. Enter : Master Code [Factory set Default Master Code: x - x - x - x - x - x]
      One Beep sounds, which indicates the entry is valid
      Please see your user manual for the factory set Codes or contact Tech Support.
    3. Enter : New Code [6-digits]
      One Beep sounds, which indicates the entry is valid
    4. Re-Enter : nNew Code [6-digits]
      One Beep sounds, which indicates the codes entered in previous steps are the same & the code changing process is succcessful
      If 2 Beeps sound, the changing process failed. Existing code is still valid. Repeats steps 1 - 4
    5. Record the new Master Code for safe keeping.

      NOTE:
    1. Verify the new master code at least 3 times before closing the door to make sure the code is correct.
    2. Operations between adjacent steps need be completed in 10 seconds. Otherwise, the lock system sets back to standby status.

      Add Manager
    1. Enter : Master Code & hold down last digit of Code until 1 Beep & Double Beeps sound
    2. Press : 1
      1 Beep sounds, which prompts to enter a code for Manager
    3. Enter : New Manager Code [6-digits]
      1 Beep sounds, which indicates the entry is valid
    4. Re-Enter : New Manager Code [6-digits]
      1 Beep sounds, which indicates the codes entered in previous steps are the same & the adding manager process is successful
      If 2 Beeps sound, the adding process failed. Repeats steps 1 - 4

      NOTE:
    1. Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
    2. Operations between adjacent steps need be complete in 10 seconds. Otherwise, the lock system sets back to standby status.

      Add User
    1. Enter : Manager Code & hold down last digit of Code until 1 Beep & Double Beeps sound
    2. Press : 1
      1 Beep sounds, which prompts to enter a code for User
    3. Enter : New User Code [6-digits]
      1 Beep sounds, which indicates the entry is valid
    4. Re-Enter : New User Code [6-digits]
      1 Beep sounds, which indicates the codes entered in previous steps are the same & the adding user process is successful
      If 2 Beeps sound, the adding process failed. Repeats steps 1 - 4

      NOTE:
    1. Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
    2. Operations between adjacent steps need be complete in 10 seconds. Otherwise, the lock system sets back to standby status.

      Open Lock [Single User Mode]
    1. Enter : User Code OR Manager Code
      Lock signals 1 Beep & opens
      Change Manager or User Code
    1. Enter : 0-0-0-0-0-0
      1 Beep sounds, which indicates the entry is valid & the system is waiting for code changing
    2. Enter : Existing Code OR Manager Code OR User Code [any 6-digit code] 1 Beep sounds, which indicates the entry is valid
    3. Enter : New Code [6-digits]
      1 Beep sounds, which indicates the entry is valid
    4. Re-Enter : New Code [6-digits]
      1 Beep sounds, which indicates the codes entered in previous steps are the same & the code changing process is successful
      If 2 Beeps sound, the changing process failed. The existing code is still valid. Repeat steps 1 - 4

      NOTE:
    1. Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
    2. Operations between adjacent steps need be complete in 10 seconds. Otherwise, the lock system sets back to standby status.

      Disable Manager
    1. Enter : Master Code & hold down Last Digit of Code until 1 Beep & Double Beeps sound
    2. Press : 2
      Double Beeps sound, the disabling manager is successful
    3. Enter : Disabled Manager Code to make sure the code is disabled
      Enable Manager
    1. Enter : Master Code & hold down Last Digit of Code until 1 Beep & then Double Beeps sound
    2. Press : 1
      Double Beeps sound, the enabling manager is successful

      NOTE:
    1. Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
    2. Operations between adjacent steps need be complete in 10 seconds. Otherwise, the lock system sets back to standby status.

      Delete Manager
    1. Enter : Master Code & hold down Last Digit of Code until 1 Beep & Double Beeps sound
    2. Press : 3
      Double Beeps sound, the deleting manager is successful
    3. Enter : Deleted Manager Code to make sure the code is deleted
      Disable User
    1. Enter : Manager Code & hold down Last Digit of Code until 1 Beep & Double Beeps sound
    2. Press : 2
      Double Beeps sound, the disabling user is successful
    3. Enter : Disabled User Code to make sure the code is disabled
      Enable User
    1. Enter : Manager Code & hold down Last Digit of Code until 1 Beep & Double Beeps sound
    2. Press : 1
      Double Beeps sound, the enabling user is successful
      NOTE:
    1. Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
    2. Operations between adjacent steps need be complete in 10 seconds. Otherwise, the lock system sets back to standby status.

      Delete User
    1. Enter : Master Code & hold down Last Digit of Code until 1 Beep & Double Beeps sound.
    2. Press : 3
      Double Beeps sound, the deleting user is successful
    3. Enter : Deleted User Code to make sure the code is deleted
      Set Single User Mode [Manager or User Code to Unlock]
    1. Enter : Master Code & hold down Last Digit of Code until 1 Beep & Double Beeps sound.
    2. Press : 0 to set the lock to Single User Mode
      Set Dual User Mode [Manager & User Code to Unlock]
    1. Enter : Master Code & hold down Last Digit of Code until 1 Beep & Double Beeps sound
    2. Press : 8 to set the lock to Dual User Mode
      Set Time Delay & Time Window Mode
    1. Enter : Master Code & hold down Last Digit of Code until 1 Beep & Double Beeps sound
    2. Press : 9
    3. Enter : a 6-digit number dddttt in the range of 001001 – 040020
      The first 3 digits is for Time Delay & the second 3 digits is for Time Window.
      The maximum Time Delay is 40 minutes
      The maximum Time Window is 20 minutes
      Example : to set a 15 minutes Time Delay & a 3 minutes Time Window - Enter : 015003

      OPERATE LOCK without TIME DELAY & TIME WINDOW
      Single User Mode
    1. Enter : User Code OR Manager Code
      The lock signals 1 Beep & opens
      Dual User Mode
    1. Enter : User Code AND Manager Code OR Manager Code AND User Codes
      Lock signals 1 Beep & opens

      OPERATE LOCK with TIME DELAY & TIME WINDOW
      Single User Mode
    1. Enter : User Code OR Manager Code
      1 Beep & 4 Beeps sounds, which indicates the lock goes into Time Delay period
      Lock signals 1 Beep every 10 seconds & 4 Beeps at the end of Time Delay period to start Time Window period
    2. Re-Enter : User Code OR Manager Code to unlock
      Dual User Mode
    1. Enter : User Code AND Manager Code OR Manager Code AND User Codes
      One Beep and then Four Beeps sound, which indicates the lock goes into Time Delay period.
    2. Lock signals 1 Beep every 10 seconds & 4 Beeps at the end of Time Delay period to start Time Window period
    3. Re-Enter : User Code AND Manager Code OR Manager Code AND User Codes to unlock

      Changing Your Battery
    1. Slide the keypad housing up & carefully pull away from mounting surface to gain access to the battery compartment.
    2. Remove 9V Alkaline Battery & replace with new one
    3. CAUTION: Hold onto the keypad housing & battery terminal to avoid pulling wires out of housing.
    4. Carefully position the keypad over the mounting screws & slide the keypad housing down. Ensure that there are no wires or cables trapped between the input pad & the safe door. Pinched cables can result in a short circuit.
    5. Battery Change : ECSL0601A-D

      Trouble Shooting
      If you have any issues with your electronic lock:
    1. Please make sure the connection from the wire to the keypad is secure
    2. Please replace the 9V Alkaline Battery with a new one.
    3. If you still have issues, please contact Mesa Safe Company Tech Support at 888.381.8514 [Mon. – Fri. 8:00am – 5:00pm PST].
SPECIFICATIONS:
  • Power Supply: DC9V
  • Power Supply Range: DC 4.5V-12V
  • Standby Current: <15μA
  • Active Current: <20mA
  • Battery Low Voltage: 5.2 ± 0.2 V
  • Working Temperature: -25°C~ +60°C
  • Working Humidity: <95%
  • Storage Temperature: -45°C~ +85°C
  • Password Length: 6 Digits
  • Mechanical System Life Span: > 100,000 Cycles
  • Model: ECSL-0601A-D
  • User's Manual Version V1.0020080108(E)
  • SecuRam Systems Inc. U.S.A.


Please contact Tech Support at 888.381.8514 for assistance.
Live Technical Support Available Monday - Friday 8:00am - 4:30pm [Pacific Standard Time]
Click Here to view our Mesa Safe Warranty.
Click Here to view our Limited Lifetime MBF Gun Safe Warranty.