MSL-300E ELECTRONIC LOCK OPERATING INSTRUCTIONS
The default Master Code is factory set to 7 - 7 - 7 - 7 - 7 - 7The default manager code is factory set to 0 - 0 - 0 - 0
How to open your safe
Single User Mode (Default Setting)
- Enter: * - Code - #
- The lock will indicate a valid code entry with a double signal and the open light will stay green for five (5) seconds.
- Turn the handle clockwise before the green light disappears
- Enter: * - 1st Code - # - 2nd Code - #
- The lock will indicate a valid code entry with a double signal and the open light will stay green for five (5) seconds.
- Turn the handle clockwise before the green light disappears.
- Entry of three (3) consecutive invalid codes starts a five (5) minute lockout period.
- You will not get any response from the keypad during this period.
Always perform this operation with the door open.
- Enter: # - Existing Master Code - #
- The set light will stay orange for ten (10) seconds.
- Enter: 1 - * - New Master Code - # - New Master Code - #, before the orange light disappears.
- If a mistake is made during the change, wait thirty (30) seconds and repeat steps 1 thru 3.
- Test the new code several times before closing the door.
- The lock will indicate a valid code change with a double signal
- The lock will indicate an invalid code chage with a triple signal and the old code is still valid.
Always perform this operation with the door open
- Enter: # - Master Code or Manager Code - #
- The set light will stay orange for ten (10) seconds.
- Enter: 2 - * - New Manager Code - # - New Manager Code - #, before the orange light disappears
- If a mistake is made during the change, wait thirty (30) seconds and repeat steps 1 thru 3.
- Test the new code several times before closing the door.
- The lock will indicate a valid code change with a double signal
- The lock will indicate an invalid code chage with a triple signal and the old code is still valid.
Always perform this operation with the door open.
- Enter: # - Master Code - #
- The set light will stay orange for ten (10) seconds.
- Enter: (User #) - * - New User Code - # - New User Code - #, before the orange light
- If a mistake is made during the activation, wait thirty (30) seconds and repeat steps 1 thru 3.
- The lock will indicate a valid code change with a double signal
- The lock will indicate an invalid code chage with a triple signal and the old code is still valid.
- Example: # - Master Code or Manager Code - # - 5 - * - New User Code - # - New User Code - #, this will activate user five.
Always perform this operation with the door open
- Enter: # - User Code - #
- The set light will stay orange for ten (10) seconds.
- Enter: # - New User Code - # New User Code - #, before the orange light disappears
- If a mistake is made during the change, wait thirty (30) seconds and repeat steps 1 - 3.
- Test the new code several times before closing the door.
- The lock will indicate a valid code change with a double signal
- The lock will indicate an invalid code chage with a triple signal and the old code is still valid.
- The Master and Manager can also change the user codes by following the Activate user codes section steps 1 thru 3.
Always perform this operation with the door open.
Deleting User Code
- Enter: # - Master Code or Manager Code - #
- The set light will stay orange for ten (10) seconds.
- Enter: (User #) - * - # - #
- Enter: # - Master Code - #
- The set light will stay orange for ten (10) seconds.
- Enter: 2 - * - # - #
- The lock will indicate a valid code change with a double signal
- The lock will indicate an invalid code chage with a triple signal and the old code is still valid.
Always perform this operation with the door open
Setting single user mode (any code to unlock)
- Enter: # - Master Code - # - 0 - # - 0 - #
- The lock will indicate a valid setting change with a double signal
- Enter: # - Master Code - # - 1 - # - 1 - #
- The lock will indicate a valid setting change with a double signal
- Enter: # - Master Code - # - 2 - # - 2 - #
- The lock will indicate a valid setting change with a double signal
- Please see the "How to open your safe" section for unlocking in dual user mode
Always perform this operation with the door open
This function will delay the opening and programming of the safe
- Enter: # - Master Code - # - (01-99) - # - (01-99) - #
- The lock will indicate a valid setting change with a double signal.
- Example: # - Master Code - # - 05 - #, this will set a five (5) minute time delay.
- Press * or # to initiate the Time Delay
- The lock will signal once every ten (10) seconds during time delay and will signal every second during the last ten (10) seconds of the time delay.
- The lock will signal twice and beep once every ten (10) seconds during hte open period. The open period length is two (2) minutes.
- During the open period you will need to enter your code.
- Enter: # - Master Code - # - 00 - # - 00 - #
- The lock will indicate a valid setting change with a double signal.
- The green LED light will signal in red when opening your safe.
- The lock is giving you a valid signal but is not unlocking.
Always perform this operation with the door open, unless the keypad is dead.
- Turn the keypad housing counter clockwise and carefully pull away from the mounting plate to expose battery compartment.
- Remove the four AAA Alkaline batteries and replace.
Caution: Hold onto battery terminal to avoid pulling wires out of housing. - Carefully position the keypad into the inserts on the mounting plate and turn keypad clockwise. Ensure that there are no wires or cables trapped between the keypad and the inserts on the mounting plate. Pinced cables result in a short circuit.