MSL-200E ELECTRONIC LOCK OPERATING INSTRUCTIONS

The Master code is factory set to 7 - 7 - 7 - 7 - 7 - 7

How to open your safe Single User Mode (Default Setting)
  1. Enter * - Code - #
  2. The lock will indicate a valid code entry with a double signal and the open light will stay green for five (5) seconds.
  3. Turn the handle clockwise before the green light disappears.
Dual User mode (Please see setting single user and dual user mode)
  1. Enter: * - 1st Code - # - 2nd Code - #
  2. The lock will indicate a valid code entry with a double signal and the open light will stay green for five (5) seconds.
  3. Turn the handle clockwise before the green light disappears.
Wrong try penalty Changing the master code ( Code length: 1 to 10 digit code)
Always perform this operation with the door open.
  1. Enter: # - Existing Master Code - #
  2. The set light will stay orange for ten (10) seconds.
  3. Enter: 1 - * - New Master Code - # - New Master Code - #, before the orange light disappears.
  4. If a mistake is made during the change, wait thirty (30) seconds and repeat steps 1 - 3.
  5. Test the new code several times before closing the door.
Activate the manager code (Code length: 1 to 10 digit code)
  1. Enter: # - Master Code - #
  2. The set light will stay orange for ten (10) seconds.
  3. Enter: 2 - * - New Manger Code - # - New Manger Code - #, before the orange light dissapears.
  4. If a mistake is made during the activation, wait thirty (30) seconds and repeat steps 1 thru 3.
Changing the manager code
Always perform this operation with the door open.
  1. Enter: # - Mster Code or Manager Code - #
  2. The set light will stay orange for ten (10) seconds.
  3. Enter: 2 - * - New Manager Code - # - New Manager Code - #, before the orange light disappears.
  4. If a mistake is made during the change, wait thirty (30) seconds and repeat steps 1 thru 3.
  5. Test the new code several times before closing the door.
Activate user codes (Code length: 1 to 10 digit code)
  1. Enter: # - Master Code or Manger Code - #
  2. The set light will stay orange for ten (10) seconds.
  3. Enter: (User #) - * - New User Code - # - New User Code - #, before the orange light dissappears. (User #: Specify which user you would like to activate 3, 4 , 5 or 6.)
  4. If a mistake is made during the change, wait thirty (30) seconds and repeat steps 1 thru 3.
Changing the user code
Always perform this operation with the door open
  1. Enter: # - User Code - #
  2. The Set light will stay orange for ten (10) seconds.
  3. Enter: # - New User Code - # - New User Code - #, before the orange light disappears.
  4. If a mistake is made during the change, wait thirty (30) seconds and repeat steps 1 thru 3.
  5. Test the new code several times before closing the door.
Deleting Codes
Deleting a user code
  1. Enter: # - Master Code or Manager Code - #
  2. The set light will stay orange for ten (10) seconds.
  3. Enter: (User #) - * - # - #
Deleting a manager code
  1. Enter: # - Master Code - #
  2. The set light will stay orange for ten (10) seconds.
  3. Enter: 2 - * - # - #
Warning Setting single user and dual user mode
Always perform this opeation with the door open
Setting single user mode (any code to unlock)
  1. Enter: # - Master Code - # - 0 - # - 0 - #
  2. The lock will indicate a valid setting change with a double signal
Setting dual user mode (any code & any code to unlock)
  1. Enter: # 0 Master Code - # - 1- # - 1 - #
  2. The lock will indicate a valid setting change with a double signal.
Setting Dual user mode (master or manager code & user code to unlock)
  1. Enter: # - Master Code - # - 2 - # - 2 - #
  2. The lock will indicate a valid setting change with a double signal.
Setting time delay
Always perform this operation with the door open
This function will delay the opening and programming of the safe
  1. Enter: # - Master Code - # - (01-99) - # - (01-99) - #
  2. The lock will indicate a valid setting change witha double signal
Operating the lock when time delay is set
  1. Press * or # to initiate the Time Delay.
  2. The lock will signal once every ten (10) seconds during time delay and will signal every second during the last ten (10) seconds during the open period.
  3. The lock will signal twice every ten (10) seconds during the open period. The open period length is two (2) minutes.
  4. During the open period you will need to enter your code.
De-Activate time delay
  1. Enter: # - Master Code - # - 00 - # - 00 - #
  2. The lock will indicate a valid setting change with a double signal.
Low battery warning Changing your batteries
  1. Turn the keypad housing to the left (counter clockwise) and carefully pull away from the mounting plate to expose battery compartment.
  2. Remove the four AAA Alkaline batteries and replace.
    Caution: Hold onto the battery terminal to avoid pulling wires out of the housing.
  3. Carefully position the keypad into the insterts on the mounting plate and turn keypad right (clockwise). Ensure that there are no wires or cables trapped between the keyapd and the inserts on the mounting plate. Pinched cables result in a short circuit.